Grundfos TP/TPE Direct-Coupled In-Line Circulator Pump Model Numbers, Type Codes & Nomenclature Explained

Learn how to read Grundfos TP/TPE direct-coupled in-line circulator pump model numbers, type codes and nameplates. Use the worked example below to identify the pump configuration and product number before selecting a replacement or spare parts.

Worked example: TP 40-160/2 A-F-A-BQQE

The yellow and bold entries below identify codes printed on this nameplate. Unhighlighted entries describe other documented options; availability depends on model, market and generation.

Grundfos TP / TPE pump

How to identify your Grundfos pump from its nameplate

Copy the complete Type designation and the separate Model or Ver. row from the tag plate. Photograph the motor plate as well: the pump plate does not necessarily contain every electrical rating.

Grundfos TP 40-160/2 A-F-A-BQQE nameplate, product number 98958098
The supplied nameplate, shown at a readable width. Highlighted markings identify the type designation and product number.

Type designation

TP 40-160/2 A-F-A-BQQE

This describes the configuration. Keep every suffix when comparing pumps.

Product number

98958098

Full identification row: A 98958098 P2 1902 5424. The eight-digit product number is separate from the production and serial codes.

Grundfos TP/TPE direct-coupled in-line circulator pump model number decoder

TP/TPE are single-stage in-line pumps. Their inlet and outlet lie on the same axis. The number after the first hyphen describes a head class; it is not the nominal impeller diameter used in the NB key.

Read this example as TP | 40 | 160 | 2 | A | F | A | BQQE.

TP — Family and drive

The family letters distinguish the pump and control arrangement.

  • TP — In-line pump with conventional motor.
  • TPE — Electronically speed-controlled pump.
  • TPD — Twin-head pump; TPED — Electronically speed-controlled twin-head pump.
  • TPE2/TPE3 and their twin-head versions use their own generation-specific designations; do not apply every legacy TP field automatically.

40 — Nominal connection size

The number refers to both the inlet and outlet.

  • 40 — DN 40 inlet and outlet ports.
  • Other numerical DN sizes identify other pipe connections.
  • DN is a nominal size. Flange drilling, pressure class and face-to-face length must still match the installation.

160 — Nominal maximum head

The TP head designation is in decimetres.

  • 160 — Nominal maximum head class of 160 dm, or 16 m.
  • It is not an impeller-diameter code.
  • The photographed pump is rated at H = 10.6 m at Q = 13.6 m³/h. Head at a flowing duty point differs from the nominal maximum-head designation.
  • Use the product curve at the actual frequency and speed for selection.

/2 — Motor pole count

Read this slash field in the TP family context.

  • 2 — Two-pole motor.
  • 4 — Four-pole variant, where available.
  • The pole count is not the measured shaft speed: rated speed also depends on frequency and motor slip.
  • Here the plate states 3450 min⁻¹. Confirm frequency and voltage from the motor plate.

A — Pump version

This is the first A after the slash field.

  • A — Basic version.
  • B — Oversize motor.
  • I — PN 6 flange variant; A3 — PN 25 variant, where specified.
  • E added to a version — ATEX approval, certificate or test report.
  • U — NEMA motor-dimension version in relevant regional keys.
  • X — Special version.
  • Combined codes must be read together; a letter does not by itself identify a particular approval certificate.

F — Pipe connection

The connection letter is separate from the DN size.

  • F — DIN flange.
  • G — ANSI/US flange; J — JIS flange, in relevant regional or older keys.
  • O — Union connection in newer keys; R — External thread in relevant older keys.
  • Confirm flange pressure class, drilling and installation dimensions from the product drawing.

A — Material execution

This is the second A in A-F-A.

  • A — Basic material execution, with cast-iron housing; impeller material depends on the TP size and generation.
  • B — Cast-iron housing with bronze/brass impeller.
  • I — Stainless-steel EN 1.4308 housing and motor stool.
  • R / S — Cast-iron housing with EN 1.4308 / EN 1.4408 stainless-steel impeller.
  • O — Ductile-iron housing with cast-iron impeller.
  • Y / Q — Ductile-iron housing with bronze/brass / EN 1.4408 impeller.
  • Z — Bronze housing and motor stool.
  • The basic code alone should not be used to assign an identical impeller alloy to every TP model.

BQQE — Shaft seal

Read design, rotating face, stationary face and secondary seal separately.

  • B — Rubber-bellows seal.
  • A — O-ring seal with fixed driver; D — balanced O-ring seal.
  • G — Bellows seal with reduced faces; R — O-ring seal with reduced faces.
  • First Q — Silicon-carbide rotating face.
  • Other rotating-face codes: A — antimony-impregnated carbon; B — resin-impregnated carbon; U — tungsten carbide, where offered.
  • Second Q — Silicon-carbide stationary face.
  • Other stationary-face codes: B — resin-impregnated carbon; U — tungsten carbide.
  • E — EPDM secondary seal and the rubber/plastic parts covered by this key, excluding the neck ring.
  • Other secondary-seal codes include V — FKM, F — FXM and P — NBR, where specified.
  • BQQE is a material/design code. The complete seal dimensions and service part depend on the pump.

Other TPE sensor and motor codes

These options are not printed on the illustrated conventional TP plate.

  • Blank sensor position — Relevant TPE Series 1000 with MGE motor and no sensor.
  • S — TPE Series 2000 with factory-fitted differential-pressure sensor.
  • NC / SC — Relevant integrated-CUE versions without / with differential-pressure sensor.
  • Extended keys may add motor-output, DOE/electrical-identification and speed fields after the seal code.
  • Examples of output codes: G — 1.1 kW; H — 1.5 kW; I — 2.2 kW.
  • Later speed codes: 1/2 — Two-pole 50/60 Hz; 3/4 — Four-pole 50/60 Hz; A/B/C — Specified E-motor speed ranges.
  • These suffix definitions have changed between generations and markets. Do not add missing suffixes to this older plate.

Read the other TP identification plate fields

FieldValue shownMeaning
ModelA 98958098 P2 1902 5424A: service model; product 98958098; site P2; 2019 week 02; serial 5424.
Q13.6 m³/hFlow stated on the plate.
H10.6 mHead at the stated flow; different from the 160 dm nominal maximum-head class.
n3450 min⁻¹Rated shaft speed.
p/t10/120 bar/°C MAXMaximum pressure/temperature marking: 10 bar / 120 °C. Check the operating envelope.
MEI≥ 0.70Minimum efficiency index; not a percentage efficiency.
ηp70.1%Hydraulic efficiency at the specified optimum point.
OriginMade in HungaryManufacturing-country marking.

Pump identification and motor identification are separate. This photograph does not show the motor voltage, current or winding connection. Record the motor nameplate when comparing replacements. The 3450 min⁻¹ speed is not a voltage specification.

Identifying a replacement pump or spare parts

For the illustrated example, record TP 40-160/2 A-F-A-BQQE and product number 98958098. The product number identifies the specific product; the type code explains its configuration. A spare-part or service-kit number is a different identifier.

Include a legible photograph of the pump name plate and motor plate, the required flow and head, liquid and temperature, and the part you want to identify. Compare the complete configuration rather than the size alone. Matching a seal code does not establish that two complete pumps are interchangeable.

Browse Grundfos TP/TPE series pumps

Back to Grundfos Pump Model Numbers, Type Codes & Nomenclature Explained