Grundfos CM/CME Multistage Pump Model Numbers, Type Codes & Nomenclature Explained
Learn how to read Grundfos CM/CME multistage pump model numbers, type codes and nameplates. Use the worked example below to identify the pump configuration and product number before selecting a replacement or spare parts.
Worked example: CME10-4 A-S-G-E-AQQE S-A-D-N
The yellow and bold entries below identify codes printed on this nameplate. Unhighlighted entries describe other documented options; availability depends on model, market and generation.

How to identify your Grundfos pump from its nameplate
Copy the complete Type designation and the separate Model or Ver. row from the tag plate. Photograph the motor plate as well: the pump plate does not necessarily contain every electrical rating.

Type designation
CME10-4 A-S-G-E-AQQE S-A-D-N
This describes the configuration. Keep every suffix when comparing pumps.
Product number
99119706
Full identification row: A 99119706 P9 2106. The eight-digit product number is separate from the production and serial codes.
Grundfos CM/CME multistage pump model number decoder
Read from left to right: CME | 10 | 4 | A | S | G | E | AQQE | S | A | D | N. A repeated letter has a different meaning in each position.
CME — Pump family
CM and CME are horizontal multistage centrifugal pumps.
- CM — Centrifugal Modular pump with a conventional motor.
- CME — Centrifugal Modular pump with integrated frequency converter.
- The E in CME denotes the electronic drive; it is separate from the E used for EPDM rubber.
10-4 — Hydraulic size and impellers
These are numerical fields, not material codes.
- 10 — Nominal flow-size designation, using the 50 Hz naming convention.
- 4 — Four impellers.
- Other CM/CME flow sizes include 1, 3, 5, 15 and 25; stage counts depend on the size.
- The plate's 60 Hz Qnom is 12 m³/h. The size number 10 is not the flow at every operating point.
A — Pump version
This is the first letter after the hydraulic size.
- A — Basic version.
- B / T — Motor one / two flange sizes larger.
- P — Motor one flange size smaller.
- E — Certificates or approvals.
- N — CME with pressure sensor.
- I / J — Altered pressure class / different maximum speed.
- M — Magnetic drive; V — CME for Multi-E; X — Special version.
- Combined codes describe combined options; for example BN combines an oversize motor and pressure sensor.
S — Pipe connection
The first S specifies the pump connections.
- S — Internal NPT thread.
- R — Internal Rp thread to ISO 7/1.
- C — Tri-Clamp; F — DIN flange; G — ANSI flange; J — JIS flange; P — PJE connection.
- Connection diameter is not supplied by this letter alone.
G — Material execution
The material position describes a component combination.
- G — Stainless-steel execution, EN 1.4401 / AISI 316 for the sleeve, shaft, impellers and chambers.
- I — Stainless-steel execution, EN 1.4301 / AISI 304.
- A — Cast-iron inlet/outlet parts with stainless-steel hydraulic components.
- X — Special material execution.
- Use the specific product's component list for individual alloys and exceptions.
E — Pump rubber parts
This position is separate from the shaft-seal code.
- E — EPDM.
- V — FKM.
- K — FFKM.
- The type key excludes the neck ring and shaft seal from this rubber-parts position.
AQQE — Shaft seal
Read the four positions independently.
- A — O-ring seal with fixed driver.
- R — Related O-ring seal with reduced seal faces, where offered.
- First Q — Silicon-carbide rotating face.
- Other rotating faces: V — aluminium oxide; U — tungsten carbide, where offered.
- Second Q — Silicon-carbide stationary face.
- Other stationary faces: B — resin-impregnated carbon; U — tungsten carbide, where offered.
- E — EPDM secondary seal.
- V — FKM; K — FFKM secondary seals.
- AQQE identifies the seal construction and materials, not the service-kit number.
S — Supply-voltage code
The S after AQQE is an electrical code.
- S — Three-phase 380–500 V, 50/60 Hz E-motor supply.
- K — Single-phase 200–240 V, 50/60 Hz E-motor.
- L — Three-phase 380–480 V, 50/60 Hz E-motor.
- M / U — Single-phase 208–230 V / 200–240 V, 60 Hz E-motor.
- T — Three-phase 440–480 V E-motor variant; confirm the frequency on its motor plate.
- Conventional CM examples: C — 1 × 220–240 V, 50 Hz; F — 3 × 220–240/380–415 V, 50 Hz.
- Supply letters vary with catalogue edition. Confirm the installed motor's own plate and wiring diagram.
A — Motor information
This A follows the supply code.
- A — Standard motor, IP55.
- B — Phase-insulated motor for converter operation.
- C — Condensing-environment version; D — Pt100 in the stator.
- E — Angular-contact bearing; F — Motor heater.
- G — Three-phase motor with overload protection.
- H — Single-phase motor without protection.
- Additional motor options are generation-dependent.
D-N — Cable entry and sensor
These are two separate suffix positions.
- D — Cable gland included.
- Other cable-entry codes: A — prepared for cable glands; B — Harting plug; C — supplied with cable.
- N — No sensor in the sensor-designation position.
- A sensor variant must be identified from the complete product configuration. Do not confuse this final N with N in the pump-version position.
Read the other CME identification plate fields
| Field | Value shown | Meaning |
|---|---|---|
| Model | A 99119706 P9 2106 | A: model/version; 99119706: product; P9: production site; 2106: 2021, week 06. |
| Frequency | 60 Hz | Frequency associated with the hydraulic ratings shown. |
| Qnom | 12 m³/h / 52.8 GPM | Nominal flow stated on the plate. |
| Hnom | 74.1 m / 105.4 PSI | Nominal head and its printed pressure equivalent. |
| Hmax | 89.6 m / 127.3 PSI | Maximum head and its printed pressure equivalent. |
| Tliq,max | 120/90 °C / 248/194 °F | Two liquid-temperature limits; read with the corresponding pressure limits. |
| PMax | 10/16 bar / 145/232 PSI / 1.0/1.6 MPa | Pressure limits paired with the temperature markings: 10 bar at 120 °C and 16 bar at 90 °C. |
| TAmb | 50 °C / 122 °F | Maximum ambient-temperature marking. |
| TF / insulation | 110 / F | Printed temperature-class and motor-insulation-class markings. |
| MEI / ηp | ≥ 0.52 / -- | Minimum efficiency index; no numerical hydraulic-efficiency value is entered. |
The hydraulic data and electrical supply are separate: the 60 Hz heading beside Qnom and Hnom does not replace the E-motor supply information. Use the performance curve for your actual speed and duty point.
Identifying a replacement pump or spare parts
For the illustrated example, record CME10-4 A-S-G-E-AQQE S-A-D-N and product number 99119706. The product number identifies the specific product; the type code explains its configuration. A spare-part or service-kit number is a different identifier.
Include a legible photograph of the pump name plate and motor plate, the required flow and head, liquid and temperature, and the part you want to identify. Compare the complete configuration rather than the size alone. Matching a seal code does not establish that two complete pumps are interchangeable.
Browse Grundfos CM/CME series pumps
Back to Grundfos Pump Model Numbers, Type Codes & Nomenclature Explained