Grundfos DDA-DDC-DDE Series Digital Dosing Pump Model Numbers, Type Codes & Nomenclature Explained
Learn how to read Grundfos DDA, DDC and DDE digital dosing pump model numbers, type keys and nameplate information. The example below follows a DDA 30-4 pump; always use the type key for the family and generation on your own plate.
Worked example: DDA 30-4 AR-PP/E/C-F-31U2U2FG
This tag plate is a DDA example within the DDA/DDC/DDE family guide.

How to identify your Grundfos dosing pump

Type designation
DDA 30-4 AR-PP/E/C-F-31U2U2FG
Product number
97722244
The Model row reads A9772224410004964P12126. Copy the complete row as well as the highlighted product number.
Grundfos DDA/DDC/DDE model number decoder
Read from left to right: DDA | 30 | 4 | AR | PP | E | C | F | 3 | 1 | U2U2 | F | G.
Yellow and bold = code shown on this example nameplate. Other options remain unhighlighted. Availability depends on pump family, size and generation; this is an identification guide, not a list of combinations that can all be ordered.
DDA — Type range
The first letters select the dosing-pump family.
- DDA — Family shown on this nameplate.
- DDC — Related digital dosing family with its own control options.
- DDE — Related family with B, P and PR control variants where available.
This example is from the SMART Digital S range. Larger SMART Digital XL pumps and connected DDA-C generations require their own type keys.
30 — Maximum dosing flow
The first number states the nominal maximum capacity in litres per hour.
- 30 — 30 l/h. Applies to this plate.
- DDA examples in this range: 7.5, 12, 17 and 30 l/h.
- DDC examples include 6, 9 and 15 l/h; DDE examples include 6 and 15 l/h in the earlier booklet. Other generations also list 17 l/h variants.
Copy the number actually printed on the plate. The set dosing rate can be lower than the maximum.
4 — Maximum pressure
Read the second number together with the flow rating.
- 4 — 4 bar. Applies to DDA 30-4.
- Other DDA pairs: 7.5-16, 12-10 and 17-7.
- DDC examples: 6-10, 9-7 and 15-4. DDE examples: 6-10 and 15-4; offerings vary by generation.
The two numbers form a model rating, not a freely interchangeable pair. The photograph separately confirms 30 l/h and 4 bar.
AR — Control variant
This field distinguishes control and monitoring functions.
- B — Basic DDE control.
- P — DDE basic control with pulse mode.
- PR — DDE pulse version with relay output.
- A — Standard DDC control.
- AR — Control with alarm relay and analogue input, used on DDA/DDC. Applies to this DDA plate.
- FC — DDA AR functions plus FlowControl.
- FCM — DDA FC functions plus flow measurement.
AR does not mean FC or FCM. Later AR-C and FCM-C designations belong to the connected DDA-C generation; the illustrated code has no -C field.
PP — Dosing-head material
This field identifies the dosing head, not every wetted component.
- PP — Polypropylene. Applies to this plate.
- PVC — Polyvinyl chloride; listed only up to 10 bar in this range.
- PV — PVDF (polyvinylidene fluoride).
- SS — Stainless steel; the earlier family key specifies EN 1.4401. Check the exact generation for the component grade.
Read the gasket and valve-ball fields as well when checking the complete wetted-material combination.
E — Gasket material
The letter between the first and second slashes identifies the gasket execution.
- E — EPDM. Applies to this plate.
- V — FKM.
- T — PTFE.
PP/E/C therefore combines a polypropylene head, EPDM gaskets and ceramic valve balls. Material compatibility cannot be determined from PP alone.
C — Valve-ball material
This is the field after the second slash.
- C — Ceramic. Applies to this plate.
- SS — Stainless-steel valve balls, EN 1.4401 in the referenced family key.
C here is not a control option or a certificate. The field's position determines its meaning.
F — Control-cube position
This F appears immediately after the material combination.
- F — Front-mounted control cube. Applies to this plate; the cube can be repositioned to the left or right.
- X — No control cube, used for DDE.
The later F near the end of the code is the mains-plug field, not a second mounting instruction.
3 — Supply voltage
Split the compact 31 into two separate fields.
- 3 — Single-phase 100–240 V AC, 50/60 Hz. Applies to this plate.
- The next digit, 1, specifies the valve type; 31 is not a 31 V rating.
Use the electrical row as a cross-check: this photograph shows 100–240 V~ and 50/60 Hz. Other supply variants must be checked against their own model documentation.
1 — Valve type
This digit follows the supply-voltage code.
- 1 — Standard valves. Applies to this plate.
- 2 — Spring-loaded valves; the family key gives 0.1 bar opening pressure at suction and discharge.
Changing the valve execution changes the configuration. Keep this digit when requesting an equivalent pump or valve-related parts.
U2U2 — Suction/discharge connections
This field describes the connection set.
- U2U2 — Metric hose set: 4/6, 6/9, 6/12 and 9/12 mm. Applies to this plate.
- U7U7 — Inch hose set: 0.17 × 1/4, 1/4 × 3/8 and 3/8 × 1/2 inch.
- AA — Rp 1/4 female threaded connection.
- VV — 1/4 NPT female threaded connection.
- XX — No connections included.
Check the actual fitted tubing and connection kit; the type key identifies the supplied configuration.
I001–I004 — Installation-set alternatives
These alternatives occupy the connection/installation-set field; none is printed on this example.
- I001 — 4/6 mm hose installation set.
- I002 — 9/12 mm hose installation set.
- I003 — 0.17 × 1/4 inch hose installation set.
- I004 — 3/8 × 1/2 inch hose installation set.
Installation sets include connections, a foot valve, an injection unit and tubing. Their flow/pressure limits depend on the set and catalogue edition; U2U2 alone must not be read as a complete installation set.
F — Mains-plug version
The F after the connection code identifies the plug.
- F — EU plug. Applies to this plate.
- B — USA/Canada.
- G — UK.
- I — Australia/New Zealand.
- E — Switzerland.
- J — Japan.
- L — Argentina.
This field identifies the supplied plug, not the supply voltage. Do not confuse plug code G with the final design code G.
G — Design/approval execution
Read the final design field separately from the plug code.
- G — Grundfos design, listed as Grundfos red in the later family booklet. Applies to this plate.
- A — Grundfos green.
- B — Grundfos black.
- X — Neutral/black.
- C — China approval.
These alternatives are catalogue- and model-dependent. Older plates and manuals may describe G simply as Grundfos or Grundfos Alldos.
C3 — Optional special variant
Some full type designations carry an additional special-variant suffix.
- C3 — Inspection certificate 3.1 to EN 10204.
- No C3 suffix is printed on this example.
Do not add a certificate suffix when copying the nameplate. Its absence is not a statement about every document that may accompany the installed pump.
Model code versus product number
The full type key describes the configuration, while 97722244 is the highlighted product number in the Model row. The complete row reads A9772224410004964P12126. Copy both the type key and this row when identifying the installed pump.
Do not use the product number as a spare-part number, or assume that all pumps called DDA 30-4 have identical materials, controls and connections. Keep the remaining serial/production characters with the photograph; their format must be read using the appropriate nameplate documentation.
Read the other identification plate fields
| Field | Value shown | Meaning |
|---|---|---|
| Model | A9772224410004964P12126 | Full identification string shown beneath the electrical information. |
| Product number | 97722244 | Highlighted identifier within the Model row. |
| U | 100–240 V~ | AC supply voltage marking. |
| f | 50/60 Hz | Supply frequency marking. |
| Imax | No value entered | No maximum current value is visible. |
| Pmax | 24 W | Maximum power marking. |
| Q | 30 l/h / 8.0 gph | Dosing flow marking. |
| P | 4 bar / 60 psi | Pressure marking. |
| Protection | IP65 / NEMA 4X | Enclosure markings shown on this plate. |
| Origin | Made in France | Manufacturing origin shown. |
Keep the complete suffix. The same flow and pressure designation alone does not identify every material, control or connection option. Use the product number together with the full type code.
Identifying a replacement pump or spare parts
Provide DDA 30-4 AR-PP/E/C-F-31U2U2FG, product number 97722244 and a clear photograph of the complete name plate. Include the liquid being dosed and the operating conditions so material suitability can be checked.
Browse Grundfos DDA/DDC/DDE digital dosing pumps
Grundfos Pump Model Numbers, Type Codes & Nomenclature Explained