Lowara HM-P, HM-S, HM-N Multistage Pump

Specifications HM-P

Flow

Head

Range

Operating pressure

Ambient temperature

Liquid temperature

Power supply

Insulation class

Enclosure class

max 14 m³/h 233 l/min

max 83 m

0,35 - 3,0 kW (0,4 - 4 HP)

10 bar

0° - 40° C

1~ -10° - +60° C,  3~ -10° - 90°C

1~ 220 - 240V , 3~ 230 - 400V

F (155° C)

IP55

Specifications HM-S

Flow

Head

Range

Operating pressure

Ambient temperature

Liquid temperature

Power supply

Insulation class

Enclosure class

max 29 m³/h 483 l/min

max 159 m

0,35 - 5,5 kW (0,4 - 7.5 HP)

16 bar

0° - 40° C

1~ -10° - +60° C,  3~ -10° - 120°C

1~ 220 - 240V , 3~ 230 - 400V

F (155° C)

IP55

Materials HM-P - HM-S

Pump body

Impeller

Elastomers

Mechanical seals

Stainless Steel AISI 304

Noryl

EPDM

Ceramic-Carbon

Specifications HM-N

Flow

Head

Range

Operating pressure

Ambient temperature

Liquid temperature

Power supply

Insulation class

Enclosure class

max 14 m³/h 233 l/min

max 83 m

0,35 - 3,0 kW (0,4 - 4 HP)

10 bar

0° - 40° C

1~ -10° - +60° C,  3~ -10° - 90°C

1~ 220 - 240V , 3~ 230 - 400V

F (155° C)

IP55

Materials HM-N

Pump body

Impeller

Elastomers

Mechanical seals

Stainless Steel AISI 316

Stainless Steel AISI 316

EPDM

Ceramic-Carbon

Identification

5HM04P07M5HVBE

5

HM

04

P

07

M

5

H

VBE

-

nominal flow m³/h

serial name

number of impellers

Material pump

7 kW rated motor power (kW x 10)

M = singel-phase, T = three-phase

50 hz

Rated voltage

Mech seal material

Overview of all types of HM-P pumps

Overview of all types of HM-S pumps

Overview of all types of HM-N pumps

Datasheet