Lenntech Water treatment & purification Lenntech Water treatment & purification

Indicators & Reagents

Lenntech deliver a wide range of indicators and reagents for the Testomat analysis instruments which are optimized for use with our photometers.

You are on the safe side when using our Lenntech reagents!
Avoid premature wear or problems with the analyzers, as they repeatedly occur, if indicators of other manufacturers or unapproved cleaning solutions are used



Testomat 2000®, Testomat ECO® and Testomat® EVO Indicators

Overview of the indicators for hardness measurement with measuring ranges.

500 ml bottles

Type of Indicator for instrument

°dH

(resolution)

°f

(resolution)

ppm CaCO3

(resolution)

mmol/l

(resolution)

Art. number
TH 2005 T2000, CAL, DUO, ECO, EVO 0.05 - 0.50 (0.01) 0.09 - 0.89 (0.02)  0.89 - 8.93 (0.2)  0.01 - 0.09 (0.01)  152005
TH 2025 T2000, CAL, DUO. ECO, EVO 0.25 - 2.50 (0.05) 0.45 - 4.48 (0.10)  4.48 - 44.8 (0.9)  0.04 - 0.45 (0.01)  152025
TH 2100 T2000, CAL, DUO, V, ECO, EVO 1.00 - 10.00 (0.20) 1.79 - 17.9 (0.40)  17.9 - 179 (3.8)  0.18 - 1.79 (0.04)  152100
TH 2250 T2000, CAL, DUO, V, ECO, EVO 2.50 - 25.00 (0.20) 4.48 - 44.8 (0.40)  44.8 - 448 (3.8)  0.45 - 4.48 (0.04)  152250
TC 2050 T2000, CAL, DUO 0.50 - 5.00 (0.50) 0.90 - 8.96 (0.90)  8.9 - 89.5  (8.9)  0.18 - 1.79 (0.18)  153050
TC 2100 T2000, CAL, DUO, V 1.00 - 20.00 (1.00) 1.79 - 35.8 (1.79)  18 - 358   
(18)
 0.36 - 7.14 (0.36)  153100
TM 2005 T2000, CAL, DUO        0.05 - 0.50 (0.01)  154005
TP 2010 T2000, CAL, DUO        0.1 - 1.5
(0.10)
 155010
TP 2100 T2000, CAL, DUO        1 - 15.0
(1.00)
 155100
TH 2005
(2 x 100 ml)
T2000, CAL, DUO 0.05 - 0.50 (0.01) 0.09 - 0.89 (0.02)  0.89 - 8.93 (0.2)  0.01 - 0.09 (0.01)  151005


100 ml bottles

Type of Indicator for instrument

°dH

(resolution)

°f

(resolution)

ppm CaCO3

(resolution)

mmol/l

(resolution)

Art. number
TH 2005 T2000, CAL, DUO, ECO, EVO 0.05 - 0.50 (0.01) 0.09 - 0.89 (0.02)  0.89 - 8.93 (0.2)  0.01 - 0.09 (0.01)  151005
TH 2025 T2000, CAL, DUO, ECO, EVO 0.25 - 2.50 (0.05) 0.45 - 4.48 (0.10)  4.48 - 44.8 (0.9)  0.04 - 0.45 (0.01)  151025
TH 2100 T2000, CAL, DUO, V, ECO, EVO 1.00 - 10.00 (0.20) 1.79 - 17.9 (0.40)  17.9 - 179 (3.8)  0.18 - 1.79 (0.04)  151100
TH 2250 T2000, CAL, DUO, V, ECO, EVO 2.50 - 25.00 (0.20) 4.48 - 44.8 (0.40)  44.8 - 448 (3.8)  0.45 - 4.48 (0.04)  151250


Testomat 2000® Reagents

Overview of the reagents for Testomat 2000® devices without hardness measurement.

Type of reagent
for instrument
Test substance

Measuring
range
[mg/l]

Art. number
CL 2250 A CL T + CL F total chlorine + free chlorine  0 – 2.5  156230
CL 2250 B CL T + CL F total chlorine + free chlorine  0 – 2.5  156231
CL 2250 C CLT total chlorine  0 – 2.5  156232
Chlorine reagent set T CL T + CL F total chlorine + free chlorine  0 – 2.5  156235
Chlorine reagent set T 50% CL T + CL F total chlorine + free chlorine  0 – 2.5  156237
reagent set A & B CLO2 chlorine dioxide   0 – 4.7   156265
CrVI 2100 A CrVI

chromate CrO42- or
chromium VI

 0 – 2.0
 0 – 1.0

 156220
CrVI 2100 B CrVI

chromate CrO42- or
chromium VI

 0 – 2.0
 0 – 1.0

 156221
FE 2005 A Fe dissolved iron (II) & (III)  0 – 1.0  156250
FE 2005 B Fe dissovled iron (II) & (III)  0 – 1.0  156251 
SO3 reagent A SO3 sulfite  0 – 20  156240 
SO3 reagent B SO3 sulfite  0 – 20  156241
Self clean cleaning solution self clean      151105
Antox solution (2 x 100 ml) Antox      151107
Brom reagent set A & B Br bromine  0 – 5.6  156295
Polymer Reagent A Polymer polymer 0 - 50  156271
Polymer Reagent B Polymer polymer 0 - 50  156272


Titromat® Indicators

Overview of the indicators for Titromat® devices.

Type of indicator
for device
Test substance Measuring
range
Resolution Art. number
TH 2500 Reagent A  TH  water hardness 2.5 - 50 °dH 2.5 °dH 155160
TH 2500 Reagent B  TH  water hardness 2.5 - 50 °dH 2.5 °dH 155161
TC 2010 Reagent A  M1  carbonate hardness 0.05 - 1 °dH 0.025 °dH 155172
TC 2010 Reagent B  M1  carbonate hardness 0.05 - 1 °dH 0.025 °dH 155173
TC 2020 Reagent A  M2  carbonate hardness 0.05 - 2 °dH 0.05 °dH 155170
TC 2020 Reagent B  M2  carbonate hardness 0.05 - 2 °dH 0.05 °dH 155171
TC 2060 Reagent A  KH  carbonate hardness 2 - 60 °dH 2 °dH 155176
TC 2060 Reagent B  KH  carbonate hardness 2 - 60 °dH 2 °dH 155177
TC 2150 Reagent A  KH  carbonate hardness 5 - 150 °dH 5 °dH 155178
TC 2150 Reagent B  KH  carbonate hardness 5 - 150 °dH 5 °dH 155179


Testomat 808/BOB Indicators

Overview of the indicators for Testomat® 808 and Testomat® BOB devices.

Type of indicator
for device
Limit value
Bottle Art. number
300 808 / F-BOB 0.02 °dH residual hardness 100 ml 140001
300 S 808 / F-BOB 0.05 °dH residual hardness 100 ml 140002
301 808 / F-BOB 0.1 °dH residual hardness 100 ml 140003
302 808 / F-BOB 0.2 °dH residual hardness 100 ml 140004
303 808 / F-BOB 0.3 °dH residual hardness 100 ml 140005
305 808 / F-BOB 0.5 °dH residual hardness 100 ml 140006
310 808 / F-BOB 1 °dH residual hardness 100 ml 140007
320 808 / F-BOB 2 °dH residual hardness 100 ml 140008
330 808 / F-BOB 3 °dH residual hardness 100 ml 140009
350 808 5 °dH residual hardness 100 ml 140010
C 5 C-BOB  0.5 °dH carbonate hardness 100 ml 140020
C 10 C-BOB  1 °dH carbonate hardness 100 ml 140021
C 15 C-BOB  1.5 °dH carbonate hardness 100 ml 140022
C 20 C-BOB  2 °dH carbonate hardness 100 ml 140023
C 30 C-BOB  3 °dH carbonate hardness 100 ml 140024
C 40 C-BOB  4 °dH carbonate hardness 100 ml 140025
M 1 M-BOB 0.1 mmol/l minus m-value 100 ml 140040
M 3 M-BOB 0.3 mmol/l minus m-value 100 ml 140041
M 5 M-BOB 0.5 mmol/l minus m-value 100 ml 140042
Overview Testomat Indicators-Reagents
For more information or quotation, please contact us: Feedback Form or call us on +31 152 610 900

About Lenntech

Lenntech BV
Distributieweg 3
2645 EG Delfgauw

tel: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com


Copyright © 1998-2018 Lenntech B.V. All rights reserved