Grundfos TPE 150-450/4 NC-A-F-A-BQQE-TW3 (99474282)

Product ID: 99474282

Request Price and Availability

Grundfos TPE 150-450/4 NC-A-F-A-BQQE-TW3 (99474282)
Part Number: 99474282

Grundfos TPE 150-450/4 NC-A-F-A-BQQE-TW3 (99474282)

Controls:
VFD product number:99616825
Frequency converter:Built-in
Type of frequency converter:CUE 3X380-500V IP55 RUG 45KW
Appr. for VFD:CE, CULUS, C-TICK
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1487 rpm
Rated flow:291.7 m³/h
Rated head:40.78 m
Actual impeller diameter:357 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Cast iron
 EN-GJL-200
 ASTM class 30
Installation:
Range of ambient temperature:-10 .. 50 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 150
Pressure rating for connection:PN 16
Port-to-port length:1000 mm
Flange size for motor:FF400
Electrical data:
Motor type:INNOMOTICS
Rated power - P2:45 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-420D/660-725Y V
Rated current:81.0/47.0 A
Starting current:800 %
Cos phi - power factor:0.84
Rated speed:1485 rpm
IE efficiency:IE4 95,4%
IE Efficiency class:IE4
Motor efficiency at full load:95.4 %
Motor efficiency at 3/4 load:95.7 %
Motor efficiency at 1/2 load:95.4 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:99454145
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:752 kg
Gross weight:918 kg
Shipping volume:3.55 m³

Spare Parts

Part NumberProduct Name
98164277Spare, Plug vent

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.