Grundfos TPE 350-320/4 NC-A-F-Y-BQQE-WW3 (93375291)

Product ID: 93375291

Request Price and Availability

Grundfos TPE 350-320/4 NC-A-F-Y-BQQE-WW3 (93375291)
Part Number: 93375291

Grundfos TPE 350-320/4 NC-A-F-Y-BQQE-WW3 (93375291)

Controls:
VFD product number:93260021
Type of frequency converter:CUE 3X380-500V IP55 RUG 90KW
Appr. for VFD:CE, CULUS, C-TICK
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1485 rpm
Rated flow:1172 m³/h
Rated head:23.6 m
Actual impeller diameter:324 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Ductile iron
 EN-GJS-400-18-LT
 ASTM Grade 60-40-18
Impeller:Bronze
 CuSn10-C
Installation:
Range of ambient temperature:-10 .. 50 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 350
Pressure rating for connection:PN 16
Port-to-port length:1400 mm
Flange size for motor:FF500
Electrical data:
Motor type:280M
Rated power - P2:90 kW
Mains frequency:50 Hz
Rated voltage:3 x 400 V
Rated current:163 A
Cos phi - power factor:0.97
Rated speed:150-1500 rpm
IE Efficiency class:IE5
Motor efficiency at full load:96.6 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:92669136
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:1370 kg
Gross weight:1490 kg
Shipping volume:3.62 m³

Spare Parts

Part NumberProduct Name
98164277Spare, Plug vent

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.