Grundfos TPD 65-170/4 A-F-B-BQQE-JW3 (96087655)

Product ID: 96087655

Request Price and Availability

Grundfos TPD 65-170/4 A-F-B-BQQE-JW3 (96087655)
Part Number: 96087655

Grundfos TPD 65-170/4 A-F-B-BQQE-JW3 (96087655)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1466 rpm
Rated flow:44.4 m³/h
Rated head:11.5 m
Actual impeller diameter:219 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Bronze
 CuSn10-C
Installation:
Range of ambient temperature:-20 .. 55 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 65
Pressure rating for connection:PN 16
Port-to-port length:475 mm
Flange size for motor:FF215
Electrical data:
Motor type:INNOMOTICS
Rated power - P2:3 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-420D/660-725Y V
Rated current:5.9/3.45 A
Starting current:730 %
Cos phi - power factor:0.83
Rated speed:1460 rpm
IE efficiency:IE3 87,7%
IE Efficiency class:IE3
Motor efficiency at full load:87.7 %
Motor efficiency at 3/4 load:88.4 %
Motor efficiency at 1/2 load:88.2 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:83V15210
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:143 kg
Gross weight:167 kg
Shipping volume:0.683 m³

Spare Parts

Part NumberProduct Name
96039352Kit, Stub shaft

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.