Grundfos TP 300-250/4 A-F-Y-BQQE-TW3 (99087606)

Product ID: 99087606

Request Price and Availability

Grundfos TP 300-250/4 A-F-Y-BQQE-TW3 (99087606)
Part Number: 99087606

Grundfos TP 300-250/4 A-F-Y-BQQE-TW3 (99087606)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1482 rpm
Rated flow:739.1 m³/h
Rated head:19.08 m
Actual impeller diameter:286 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Ductile iron
 EN-GJS-400-18-LT
 ASTM Grade 60-40-18
Impeller:Bronze
 CuSn10-C
Installation:
Range of ambient temperature:-20 .. 55 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 300
Pressure rating for connection:PN 16
Port-to-port length:1240 mm
Flange size for motor:FF400
Electrical data:
Motor type:INNOMOTICS
Rated power - P2:45 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-420D/660-725Y V
Rated current:80/46.5 A
Starting current:660 %
Cos phi - power factor:0.86
Rated speed:1478 rpm
IE efficiency:IE3 94,2%
IE Efficiency class:IE3
Motor efficiency at full load:94.2 %
Motor efficiency at 3/4 load:94.9 %
Motor efficiency at 1/2 load:95 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:99032125
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:903 kg
Gross weight:979 kg
Shipping volume:2.78 m³

Spare Parts

Part NumberProduct Name
98164277Spare, Plug vent

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.