Grundfos TP 50-80/4 A-F-A-BQQE-EY4 (98958101)

Product ID: 98958101

Request Price and Availability

Grundfos TP 50-80/4 A-F-A-BQQE-EY4 (98958101)
Part Number: 98958101
Checking availability
BUY NOW

Grundfos TP 50-80/4 A-F-A-BQQE-EY4 (98958101)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1737 rpm
Rated flow:20.6 m³/h
Rated head:6 m
Actual impeller diameter:126 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Stainless steel
 EN 1.4301
 AISI 304
Installation:
Range of ambient temperature:-20 .. 55 °C
Maximum operating pressure:10 bar
Max pressure at stated temp:10 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 50
Pressure rating for connection:PN 6/10
Port-to-port length:280 mm
Flange size for motor:FT100
Electrical data:
Motor type:INNOMOTICS
Rated power - P2:0.55 kW
Mains frequency:60 Hz
Rated voltage:3 x 440-480Y V
Rated current:1.15 A
Starting current:690 %
Cos phi - power factor:0.72
Rated speed:1750 rpm
IE efficiency:IE3 81,1%
IE Efficiency class:IE3 / NEMA Premium
Motor efficiency at full load:81.1 %
Motor efficiency at 3/4 load:80.8 %
Motor efficiency at 1/2 load:78.2 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:99900479
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:31.9 kg
Gross weight:35.4 kg
Shipping volume:0.08 m³

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.