Grundfos TP 50-430/2 A-F-B-BQQE-MW2 (98743086)

Product ID: 98743086

Request Price and Availability

Grundfos TP 50-430/2 A-F-B-BQQE-MW2 (98743086)
Part Number: 98743086
Checking availability
BUY NOW

Grundfos TP 50-430/2 A-F-B-BQQE-MW2 (98743086)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:3507 rpm
Rated flow:43.1 m³/h
Rated head:36.7 m
Actual impeller diameter:161 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Bronze
 CuSn10-C
Installation:
Range of ambient temperature:-30 .. 60 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 50
Pressure rating for connection:PN 16
Port-to-port length:440 mm
Flange size for motor:FF265
Electrical data:
Motor type:132SB
Rated power - P2:7.5 kW
Mains frequency:60 Hz
Rated voltage:3 x 400-480D/690Y V
Rated current:13,8-12,0/8,10 A
Starting current:750-1050 %
Cos phi - power factor:0.88-0.82
Rated speed:3500-3530 rpm
IE Efficiency class:NEMA Premium / IE3 60Hz
Motor efficiency at full load:90.2 %
Motor efficiency at 3/4 load:90.9-90.7 %
Motor efficiency at 1/2 load:91.1-89.7 %
Number of poles:2
Enclosure class (IEC 34-5):55 Dust/Jetting
Insulation class (IEC 85):F
Motor No:87370232
Others:
Minimum efficiency index, MEI ≥:0.57
Net weight:107 kg
Gross weight:124 kg
Shipping volume:0.395 m³

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.