Grundfos TP 65-630/2 A-F-A-BQQE-PW2 (96089602)

Product ID: 96089602

Request Price and Availability

Grundfos TP 65-630/2 A-F-A-BQQE-PW2 (96089602)
Part Number: 96089602

Grundfos TP 65-630/2 A-F-A-BQQE-PW2 (96089602)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:3543 rpm
Rated flow:66.8 m³/h
Rated head:54.8 m
Actual impeller diameter:180 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Cast iron
 EN-GJL-200
 ASTM class 30
Installation:
Range of ambient temperature:-30 .. 60 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 65
Pressure rating for connection:PN 16
Port-to-port length:475 mm
Flange size for motor:FF300
Electrical data:
Motor type:160LB
Rated power - P2:18.5 kW
Mains frequency:60 Hz
Rated voltage:3 x 400-480D/690Y V
Rated current:33,2-28,0/16,6 A
Starting current:760-1100 %
Cos phi - power factor:0.88-0.84
Rated speed:3530-3560 rpm
IE Efficiency class:NEMA Premium / IE3 60Hz
Motor efficiency at full load:91.7 %
Motor efficiency at 3/4 load:92.5-93.1 %
Motor efficiency at 1/2 load:92.3-91.8 %
Number of poles:2
Enclosure class (IEC 34-5):55 Dust/Jetting
Insulation class (IEC 85):F
Motor No:87420023
Others:
Minimum efficiency index, MEI ≥:0.52
Net weight:177 kg
Gross weight:201 kg
Shipping volume:0.56 m³

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.