Grundfos TP 200-160/4 A3-F-O-DQQE-OW3 (93426832)

Product ID: 93426832

Request Price and Availability

Grundfos TP 200-160/4 A3-F-O-DQQE-OW3 (93426832)
Part Number: 93426832

Grundfos TP 200-160/4 A3-F-O-DQQE-OW3 (93426832)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-40 .. 140 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1481 rpm
Rated flow:412.4 m³/h
Rated head:10.15 m
Actual impeller diameter:226-218 mm
Primary shaft seal:DQQE
Code for shaft seal:DQQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Ductile iron
 EN-GJS-400-18-LT
 ASTM Grade 60-40-18
Impeller:Cast iron
 EN-GJL-200
 ASTM class 30
Installation:
Range of ambient temperature:-20 .. 55 °C
Maximum operating pressure:25 bar
Max pressure at stated temp:25 bar / 140 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 200
Pressure rating for connection:PN 25
Port-to-port length:900 mm
Flange size for motor:FF300
Electrical data:
Motor type:WEG
Rated power - P2:15 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-415D/660Y V
Rated current:28,9-27,8/16,6 A
Starting current:700-780 %
Cos phi - power factor:0.84
Rated speed:1470 rpm
IE efficiency:IE4 93,9%
IE Efficiency class:IE4
Motor efficiency at full load:93.9 %
Motor efficiency at 3/4 load:93.6 %
Motor efficiency at 1/2 load:96.2-92.7 %
Number of poles:4
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:93123977
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:450 kg
Gross weight:547 kg
Shipping volume:1.68 m³

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.