Grundfos SEV.80.80.13.A.Ex.4.50D.Q (92887789)

Product ID: 92887789

Request Price and Availability

Grundfos SEV.80.80.13.A.Ex.4.50D.Q (92887789)
Part Number: 92887789

Grundfos SEV.80.80.13.A.Ex.4.50D.Q (92887789)

Non-self-priming, single-stage, centrifugal pump designed for handling wastewater, process water and unscreened raw sewage. The pump is designed for intermittent and continous operation. The liquidless and maintenance free cooling system ensures that the pump can be used for submerged or dry installation. The efficient SuperVortex impeller provides passage of long fibres and solids up to 80 mm and is suitable for wastewater with a dry matter content of up to 5 %. A unique stainless-steel clamp assembling system enables quick and easy disassembly of the pump from the motor unit for service and inspection. No special tools are required.

Controls:
Moisture sensor:with moisture sensors
Water-in-oil sensor:with water-in-oil sensor
Temp. sensor:Y
Liquid:
Liquid temperature range:10 .. 40 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Rated flow:8.97 l/s
Maximum flow:18.1 l/s
Rated head:5.9 m
Type of impeller:SUPER VORTEX
Max. Particle:80 mm
Max. hydraulic efficiency:44 %
Approvals:EN12050-1
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN 1561 EN-GJL-250
Impeller:Stainless steel
 EN 1.4408
Shaft seal:SiC/SiC
Secondary shaft seal:CER/CARNBR
Installation:
Range of ambient temperature:0 .. 40 °C
Maximum operating pressure:6 bar
Type of inlet connection:DIN
Type of outlet connection:DIN
Size of inlet connection:DN 80
Size of outlet connection:DN 80
Pressure rating for outlet connection:PN 10
Maximum installation depth:7 m
Inst dry/wet:DRY/SUBMERGED
Auto coupling:96090993
Electrical data:
Power input P1:1.8 kW
Rated power - P2:1.3 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-415 V
Voltage tolerance:+6/-10 %
Max starts per hour:20
Rated current:3.8 A
Rated current at 3/4 load:3.2 A
Rated current at 1/2 load:2.9 A
Starting current:22 A
Rated current at no load:2.5 A
Cos phi - power factor:0.72
Cos phi - p.f. at no load:0.15
Cos phi - p.f. at 3/4 load:0.63
Cos phi - p.f. at 1/2 load:0.51
Rated speed:1440 rpm
Locked-rotor torque:23 Nm
Breakdown torque:28 Nm
Moment of Inertia:0.0165 kg m²
Motor efficiency at full load:71.7 %
Motor efficiency at 3/4 load:69.6 %
Motor efficiency at 1/2 load:63.9 %
Number of poles:4
Method of start:Direct-on-line (DOL)
Enclosure class (IEC 34-5):IP68
Insulation class (IEC 85):F
Explosion proof:yes
Ex-protection standard:Ex db eb h mb IIB T4, T3 Gb
Built-in motor protection:PTO
Thermal protection:Internal
Power cable type:Lyniflex
Length of power cable:10 m
Power plug:No plug
Others:
Net weight:114 kg
Gross weight:126 kg

Applications

  • Commercial wastewater — Commercial buildings have vastly different requirements for wastewater transfer. Grundfos supplies wastewater pumps and lift station pumps ensure superior reliability and safety, as well as high efficiency.
  • Flood control — Grundfos supplies complete flood control systems to protect urban and rural areas, infrastructure and large cities from flooding. Our innovative solutions meet the high-flow and low-head requirements at the flood pumping station or pump gate.
  • Industrial wastewater treatment & reuse — Grundfos offers solutions that add value to every step of wastewater treatment required for safe and compliant discharge or for water reuse in your facility. You get the most efficient treatment combined with intelligent measurement and control for maximum safety and minimum downtime.
  • Wastewater transport — When continuously transporting wastewater, you need reliable and optimised solutions for wastewater pumping stations and networks. Better system design, for example by using CFD simulations, tackles hydraulic issues in advance, reduces downtime and minimises risk.
  • Wastewater treatment — Treating wastewater is about maintaining optimal and effective processes at mechanical, biological and chemical treatment stages. A full-line supplier, Grundfos ensures that hydraulic stability is maintained and capacity not exceeded for all processes.