Grundfos UPS 25-60 N 180
Product ID: 96913058
Request Price and Availability
Grundfos UPS 25-60 N 180
Grundfos UPS 25-60 N 180
UPS 25-60 N 180
The pump is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 2-step speed selector. The pump is characterized by:
The pump is of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricatd by the pumped liquid. The pump has 2-step speed selector. The pump is characterized by:
|
The motor is a 3-phase motor. No additional motor protection is required.
| Specification | Value | |
|---|---|---|
| Liquid: | ||
| Pumped liquid: | Water | |
| Liquid temperature range: | 2 .. 110 °C | |
| Liquid temperature during operation: | 60 °C | |
| Density: | 983.2 kg/m³ | |
| Technical: | ||
| TF class: | 110 | |
| Approvals on nameplate: | CE,EAC | |
| Materials: | ||
| Pump housing: | Stainless steel | |
| DIN W.-Nr. 1.4301 | ||
| Impeller: | Composite, PES/PP | |
| Installation: | ||
| Amb. max at 80 dgr C liquid: | 80 °C | |
| Maximum operating pressure: | 10 bar | |
| Pipe connection: | G 1 1/2 | |
| Pressure rating: | PN 10 | |
| Port-to-port length: | 180 mm | |
| Electrical data: | ||
| Power input in speed 2: | 140 W | |
| Max. power input: | 130 W | |
| Mains frequency: | 50 Hz | |
| Rated voltage: | 3 x 400 V | |
| Current in speed 2: | 0.24 A | |
| Current in speed 3: | 0.21 A | |
| Starting current speed 2: | 0.3 A | |
| Max. starting current: | 0.31 A | |
| Enclosure class (IEC 34-5): | IP42 | |
| Insulation class (IEC 85): | H | |
| Others: | ||
| Net weight: | 2.5 kg | |
| Gross weight: | 2.7 kg | |
| Shipping volume: | 0.004 m³ | |