Grundfos TPE 32-50/2 A-O-A-BQQE-AWB (98525615)

Product ID: 98525615

Request Price and Availability

Grundfos TPE 32-50/2 A-O-A-BQQE-AWB (98525615)
Part Number: 98525615
Checking availability
BUY NOW

Grundfos TPE 32-50/2 A-O-A-BQQE-AWB (98525615)

Controls:
Frequency converter:Built-in
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:2800 rpm
Rated flow:4.91 m³/h
Rated head:3.29 m
Actual impeller diameter:68 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-150
 ASTM class 25
Impeller:Composite
 PES+30% GF
Installation:
Range of ambient temperature:-20 .. 50 °C
Maximum operating pressure:10 bar
Max pressure at stated temp:10 bar / 120 °C
Pipe connection standard:ISO 228-1
Type of connection:G
Size of connection:DN 32
 2 inch
Pressure rating for connection:PN 10
Port-to-port length:180 mm
Flange size for motor:FT85
Electrical data:
Motor type:71A
Rated power - P2:0.12 kW
Mains frequency:50 Hz
Rated voltage:1 x 200-240 V
Rated current:1.75-1.5 A
Cos phi - power factor:0.95
Rated speed:360-4000 rpm
IE Efficiency class:IE5
Motor efficiency at full load:81.1 %
Number of poles:2
Enclosure class (IEC 34-5):IP55
Insulation class (IEC 85):F
Motor No:98667062
Others:
Net weight:12.5 kg
Gross weight:14.5 kg
Shipping volume:0.045 m³
Danish VVS No.:382000150
Finnish LVI No.:4616369
Country of origin:HU
Custom tariff no.:84137051

Spare Parts

Part NumberProduct Name
98164277Spare, Plug vent
98284950Kit, Shaft seal BQQE

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.