Grundfos TP 40-90/4 A-F-A-BQQE-CW3 (98958141)

Product ID: 98958141

Request Price and Availability

Grundfos TP 40-90/4 A-F-A-BQQE-CW3 (98958141)
Part Number: 98958141

Grundfos TP 40-90/4 A-F-A-BQQE-CW3 (98958141)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:1370 rpm
Rated flow:6 m³/h
Rated head:5.1 m
Actual impeller diameter:145 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Stainless steel
 EN 1.4301
 AISI 304
Installation:
Range of ambient temperature:-30 .. 40 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 40
Pressure rating for connection:PN 16
Port-to-port length:320 mm
Flange size for motor:FT85
Electrical data:
Motor type:71B
Rated power - P2:0.25 kW
Mains frequency:50 Hz
Rated voltage:1 x 220-230 V
Rated current:2.14 A
Starting current:220 %
Cos phi - power factor:0.97
Rated speed:1350-1370 rpm
Motor efficiency at full load:57.0-55.0 %
Number of poles:4
Enclosure class (IEC 34-5):55 Dust/Jetting
Insulation class (IEC 85):F
Motor No:86215101
Others:
Minimum efficiency index, MEI ≥:0.70
Net weight:25.2 kg
Gross weight:28.7 kg
Shipping volume:0.08 m³
Country of origin:HU
Custom tariff no.:84137051

Spare Parts

Part NumberProduct Name
98164277Spare, Plug vent
98313337Kit, Shaft seal

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.