Grundfos TP 40-60/2 A-F-A-BQQE-CW1 (98122409)

Product ID: 98122409

Request Price and Availability

Grundfos TP 40-60/2 A-F-A-BQQE-CW1 (98122409)
Part Number: 98122409
Checking availability
BUY NOW

Grundfos TP 40-60/2 A-F-A-BQQE-CW1 (98122409)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:-25 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:2770 rpm
Rated flow:10.4 m³/h
Rated head:4.6 m
Actual impeller diameter:70 mm
Primary shaft seal:BQQE
Code for shaft seal:BQQE
Curve tolerance:ISO9906:2012 3B2
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Stainless steel
 EN 1.4301
 AISI 304
Installation:
Range of ambient temperature:-30 .. 60 °C
Maximum operating pressure:10 bar
Max pressure at stated temp:10 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 40
Pressure rating for connection:PN 6/10
Port-to-port length:250 mm
Flange size for motor:FT85
Electrical data:
Motor type:71A
Rated power - P2:0.25 kW
Mains frequency:50 Hz
Rated voltage:3 x 220-255D/380-440Y V
Rated current:1.12/0.65 A
Starting current:570-620 %
Cos phi - power factor:0.83-0.71
Rated speed:2840-2880 rpm
IE Efficiency class:IE3
Motor efficiency at full load:77.5-77.2 %
Motor efficiency at 3/4 load:76.8-74.5 %
Motor efficiency at 1/2 load:72.7-68.4 %
Number of poles:2
Enclosure class (IEC 34-5):55 Dust/Jetting
Insulation class (IEC 85):F
Motor No:85105501
Others:
Minimum efficiency index, MEI ≥:0.60
Net weight:19.9 kg
Gross weight:23.4 kg
Shipping volume:0.08 m³
Finnish LVI No.:4616025
Norwegian NRF no.:9043539
Country of origin:HU
Custom tariff no.:84137051

Spare Parts

Part NumberProduct Name
98313337Kit, Shaft seal

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.