Grundfos TP 80-400/2 A-F-B-BAQE-OW1 (96108743)

Product ID: 96108743

Request Price and Availability

Grundfos TP 80-400/2 A-F-B-BAQE-OW1 (96108743)
Part Number: 96108743

Grundfos TP 80-400/2 A-F-B-BAQE-OW1 (96108743)

Controls:
Frequency converter:None
Liquid:
Pumped liquid:Water
Liquid temperature range:0 .. 120 °C
Selected liquid temperature:20 °C
Density:998.2 kg/m³
Technical:
Pump speed on which pump data are based:2945 rpm
Rated flow:115 m³/h
Rated head:34.7 m
Actual impeller diameter:173 mm
Primary shaft seal:BAQE
Code for shaft seal:BAQE
Curve tolerance:ISO9906:2012 3B
Materials:
Pump housing:Cast iron
 EN-GJL-250
 ASTM class 35
Impeller:Bronze
 CuSn10-C
Installation:
Range of ambient temperature:-30 .. 60 °C
Maximum operating pressure:16 bar
Max pressure at stated temp:16 bar / 120 °C
Pipe connection standard:EN 1092-2
Type of connection:DIN
Size of connection:DN 80
Pressure rating for connection:PN 16
Port-to-port length:440 mm
Flange size for motor:FF300
Electrical data:
Motor type:160MD
Rated power - P2:15 kW
Mains frequency:50 Hz
Rated voltage:3 x 380-415D/660-690Y V
Rated current:28,0-26,0/16,2-15,6 A
Starting current:660-780 %
Cos phi - power factor:0.89-0.87
Rated speed:2930-2950 rpm
IE Efficiency class:IE3
Motor efficiency at full load:91.9 %
Motor efficiency at 3/4 load:92.4-92.7 %
Motor efficiency at 1/2 load:92.4-92.3 %
Number of poles:2
Enclosure class (IEC 34-5):55 Dust/Jetting
Insulation class (IEC 85):F
Motor No:87420022
Others:
Minimum efficiency index, MEI ≥:0.68
Net weight:168 kg
Gross weight:205 kg
Shipping volume:0.56 m³

Applications

  • Commercial air conditioning — Improve user comfort and reduce life-cycle costs with intelligent pumps that integrate easily into your air-based or hydronic cooling system.

category

  • Inline single stage pumps
    In-line single-stage pumps are typically used in commercial buildings for air-conditioning and heating applications. The pumps are equipped with standard motors and mechanical shaft seals. They are close-coupled, meaning that the pump and motor are two separate units, making them less sensitive to impurities in the pumped liquid.