Compact wastewater lifting station consist a package of one or two 450 litre collecting tanks, two horizontal submersible sewage pumps of the SE range, controller incl. analogue level sensor and connection accessories.
The 450 liter tank is made of airtight, corrosion free polyethylene and absolute gas and odour free. It is provided with
|
Horizontal sewage pumps provides single channel impeller or vortex impeller for every request
|
Isolating valves, non-return valves, discharge pipes, a manually operated diaphragm pump, bolts and gaskets as well as a third 450-litre tank are available as accessories.
An LC221 controller with microprocessor is equipped with display for full monitoring possibilities. The pump and sensor are connected to the controller with 4m or 10m cable and tube length. The power supply cable is 1,5m with plug (incl. phase inverter for 3 phase motor) Contactless, piezo resistive pressure sensor pluggable inside the cabinet, monitored by controller, accurate to the millimetre shown on display. Blockage free pressure tube inside the tank without movable parts inside wastewater.
The controller offer thermal motor protection and monitoring of pump operation. The thermal motor protection consists of thermal switches in the winding.
Controller functions:
|
|
|
– pump running – pump failure – high water-level alarm – common fault. 6 digital inputs for the following functions:
– connecting a pressure sensor board (pre-assembled) – connecting an analogue sensor (4-20mA or 0-5V) – connecting up to four level switches or pressure switches instead of analogue sensor – connecting a separate level switch to be used for flood detection outside the Multilift. Lifting stations are often installed in a sump inside the basement - the lowest point in the building. In case of e.g. groundwater inflow or water pipe burst, an alarm will be indicated by the controller. – connecting an external alarm reset – connecting the thermal switch of the motor.
The Multilift range is designed due to the standard EN12050-1, approved and monitored by external institute LGA. Further approvals are VDE, GHOST, CB, EMV
| Specification | Value | |
|---|---|---|
| Technical: | ||
| Type of impeller: | SINGLE CHANNEL | |
| Maximum particle size: | 80 mm | |
| Primary shaft seal: | SIC/SIC | |
| Secondary shaft seal: | CARBON/CERAMICS | |
| Max. hydraulic efficiency: | 70 % | |
| Approvals on nameplate: | EN 12050-1 | |
| Materials: | ||
| Pump housing: | Cast iron GG20 | |
| EN-JL1030 | ||
| Impeller: | Cast iron GG20 | |
| EN-JL1030 | ||
| Tank: | Polyethylene | |
| Installation: | ||
| Maximum ambient temperature: | 40 °C | |
| Maximum operating pressure: | 10 bar | |
| Flange standard: | DIN | |
| Pump outlet: | 100 | |
| Pressure rating: | PN 10 | |
| Maximum installation depth: | 2 m | |
| Liquid: | ||
| Maximum liquid temperature: | 40 °C | |
| Density: | 998.2 kg/m³ | |
| Electrical data: | ||
| Power input - P1: | 2 x 6.5 kW | |
| Rated power - P2: | 2 x 5.5 kW | |
| Mains frequency: | 50 Hz | |
| Rated voltage: | 3 x 380-415 V | |
| Voltage tolerance: | +6/-10 % | |
| Max starts per. hour: | 60 | |
| Rated current: | 13,3-13,8 A | |
| Rated current at 3/4 load: | 11 A | |
| Rated current at 1/2 load: | 9.5 A | |
| Starting current: | 87 A | |
| Rated current at no load: | 8.3 A | |
| Cos phi - p.f. at no load: | 0,1 | |
| Cos phi - p.f. at 3/4 load: | 0,65 | |
| Cos phi - p.f. at 1/2 load: | 0,52 | |
| Rated speed: | 1455 rpm | |
| Locked-rotor torque: | 98 Nm | |
| Breakdown torque: | 122 Nm | |
| Moment of inertia: | 0.1295 kg m² | |
| Motor efficiency at full load: | 83.9 % | |
| Motor efficiency at 3/4 load: | 83.3 % | |
| Motor efficiency at 1/2 load: | 81.0 % | |
| Number of poles: | 4 | |
| Start. method: | star/delta | |
| Enclosure class (IEC 34-5): | IP68 | |
| Insulation class (IEC 85): | F | |
| Length of cable: | 10 m | |
| Cable type: | H07RN-F | |
| Controls: | ||
| Moisture sensor: | without moisture sensors | |
| Water-in-oil sensor: | without water-in-oil sensor | |
| Tank: | ||
| Total volume of tank(s): | 900 l | |
| Total effective volume of collecting tank at 180 mm inlet: | 120 l | |
| Total effective volume of collecting tank at 250 mm inlet: | 240 l | |