The present investigation was undertaken to shed light on the failure of some 90/10 Cu-Ni condenser tubes in a MSF distiller. The tubes showed numerous tiny pits of unusual features. Particles of C were discovered inside the tubes and were suspected of initiating micro-galvanic cells leading to pitt
Desalination 172 (2005)
|
|
An early stage of localized corrosion, i.e. pitting and crevice corrosion, of a pure copper and a brass in uncoated and coated conditions in seawater was investigated in situ by a new non-destructive testing (NDT) method. The new method of localized corrosion detection is based on the optical corros
Desalination 135 (2001)
|