Crevice corrosion
1 - 2 of 2 results
|
An early stage of localized corrosion, i.e. pitting and crevice corrosion, of a pure copper and a brass in uncoated and coated conditions in seawater was investigated in situ by a new non-destructive testing (NDT) method. The new method of localized corrosion detection is based on the optical corros
Desalination 135 (2001)
|
|
A field test in a multi-stage flash (MSF) once-through plant has been evaluated. Six metallic construction materials, five stainless steels and one nickel base alloy, were exposed for a period of 28 months in the hot chlorinated and air saturated seawater stream of the first flash chamber at a tempe
Desalination 124 (1999)
|