Characteristics of a vibration membrane in water recovery from fine carbon-loaded wastewater

Desalination 160 (2004) 83-90

Authors

Abstract

A conventional coagulation and settlement method was used for the treatment of fine carbon-loaded wastewater from TV picture tube plants. The method is generally costly and a large amount of solid waste was created. The application of a vibration membrane to deal with this kind of wastewater has proven to be cost effective. The recovered water can be reused and the concentrated fine carbon is likely to be recycled back to the production process. This work presents a parametric study on water recovery from fine carbon-loaded wastewater using a vibration membrane. Parameters considered were the vibration characteristics, type of membrane, and concentration.

Conclusion

A VSEP unit was used to test the fine carbon wastewater with a Teflon membrane. The cake formation on the membrane surface due to deposition of solid carbon particles dominated [1] O. Al-Akoum, M.Y. Jaffrin, L.H. Ding. P. Paullier and C. Vanhoutte, An hydrodynamic investigation of microfiltration and ultrafiltration in a vibrating membrane module, J. Membr. Sci., 197 (2002) 37–52. [2] O. Al-Akoum, M.M. Bonin, L.H Ding, C. Fonade, P Aptel and M.Y Jaffrin, Comparison of three different systems, used for flux enhancement: application to crossflow filtration of yeast suspensions, Desalination, 147 (2002) 31–36. [3] S. Ali, P.Boblak, E. Capili and S. Milidivich, Membrane Separation. [4] VSEP New Logic Series L Ver 2.1 Operating Manual.

Tags

Carbon wastewater, Membrane vibration, Shear-enhanced filtration