Lenntech <!-- PLUGIN:LANGUAGE:water_treatment_and_purification --> Lenntech <!-- PLUGIN:LANGUAGE:water_treatment_and_purification -->

Medium Reverse Osmosis Plant

Medium Demineralisation System

Contact us for turnkey industrial projects - Send your project specification to info@lenntech.com

Lenntech provides Medium reverse osmosis plant up to 3.5 m3/h

Low energy or high rejection membranes

All equipment mounted on stainless steel 304 skid

Available in complete Stainless Steel piping

Standard control with RO micro-controller and conductivity display

Advanced control with flow, pressure, pH and conductivity transmitters for data monitoring, normalisation and SCADA.

The system includes:

5 microns filter
High pressure pump
RO or NF membranes 8 " membranes
Fiber glass pressure vessels
Standard or advanced instrumentation
Option: antiscalant dosing station

 

Type BWRO-M

1500

2000

2500

3000

3500

Permeate flow * l/h

1500

2000

2500

3000

3500

Feed flow l/h (80% recovery)

1875

2500

3125

3750

4375

Salt Rejection

>95% Reverse Osmosis, 90% Nanofiltration

Connections

 

 

 

Feed

DN 32

DN 32

DN 32

DN 32

DN 32

Permeate

DN 25

DN 25

DN 25

DN 25

DN 25

Concentrate

DN 25

DN 25

DN 25

DN 25

DN 25

Power 400V, 50Hz**

2.2 kW

4.0 kW

4.0 kW

4.0 kW

4.0 kW

Dimensions (mm)

 

 

 

 

 

Length

2700

Width

800

Height

1800

 

 

* under standard conditions: TDS< 1500ppm, temperature = 12oC, pH = 7.5
** Also available in 60 Hz

These data are given for information purpose only. They are subject to modifications depending on the water quality.

Reverse Osmosis or Nanofiltration units often required pre-treatment for the following parameters:

- Suspended solids
- TOC, COD/BOD, hydrocarbons
- Iron and manganese
- Hardness

Lenntech provides all kinds of pre-treatment required before your RO, like multimedia filters, water softeners or de-ironing filters, according to your water analysis and process requirements.

Please send us your water analysis for further information.



Back to Reverse Osmosis Plants

What is reverse osmosis?

Reverse Osmosis membrane cleaning

 

For a direct quotation, please contact us: Feedback Form or call us on +31 152 610 900

About Lenntech

Lenntech BV
Rotterdamseweg 402 M
2629 HH Delft

tel: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com


Copyright © 1998-2017 Lenntech B.V. All rights reserved