Filmtec BW30-365

Filmtec BW30-365 membrane

High Rejection Brackish Water RO Element

BW30-365 has been the element of choice for system designers, OEMs and system operators requiring consistently high performance and maximum element life when treating difficult feed waters.

Product name BW30-365
Part number 80773
Nominal Active Surface Area 365 (34) ft2 (m2)
Permeate Flow Rate 9,500 (36) gpd (m3/d)
Stabilized Salt Rejection 99.5 %
2. Flow rates for individual elements may vary but will be no more than 15% below the value shown. 3. Sales specifications may vary as design revisions take place. 4. Active area guaranteed +/-3%. Active area as stated by FilmTec is not comparable to nominal membrane area often stated by some manufacturers. Measurement method described in Form No. 609-00434.
Membrane Type Polyamide Thin-Film Composite (Filmtech)
Maximum Operating Temperature 113°F (45°C)
Maximum Feed Flow Rate 14 (3.2) gpm (m3/hr)
Maximum pressure drop 15 psig (1.0 bar)
pH Range, Continuous Operation 2-11
pH Range, Short Term Cleaning 1-13
Maximum Feed Silt Density Index SDI 5
Free Chlorine Tolerance < 0.1 ppm

Product Dimensions in Inches (mm) A B C
BW30-365 40.0 (1,016) 1.125 ID (29) 7.9 (201)

Important Information:

Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed. Please refer to the application information literature entitled “Start-Up Sequence” (Form No. 609-02077) for more information.

Operation Guidelines:

Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows: Feed pressure should be increased gradually over a 30-60 second time frame. Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds. Permeate obtained from first hour of operation should be discarded.

General Information:

Keep elements moist at all times after initial wetting. If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution. The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements. Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar). Avoid static permeate-side backpressure at all times.

Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system. Notice: No freedom from any patent owned by Seller or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Seller assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.

BW30365: This element offers proven performance, high rejection and outstanding robustness and durability across a wide range of feed conditions where unit price is a key driver. • Features the industry’s thickest feed spacer (34 mil) to lessen the impact of fouling. • May be cleaned over the widest pH range (pH 1-13) for the most effective cleaning. • The BW30-365 is best suited for systems operating on challenging feed streams, where reliable pretreatment is not an option, or where maximum cleanability delivers value.

Lenntech can also help you with similar brackish and seawater filters or filtration systems for optimum water purification and liquid filtration. Also we can provide other Filmtec type replacement membranes
Please feel free to contact us for any information on reverse osmosis water filters.

* Filmtec membranes are a trademark of The Dow Chemical Company



Lenntech BV

Rotterdamseweg 402 M
2629 HH Delft
The Netherlands

tel: (+31)(0)15 2610900

fax: (+31)(0)15 26.16.289

e-mail: info@lenntech.com