Lenntech <!-- PLUGIN:LANGUAGE:water_treatment_and_purification --> Lenntech <!-- PLUGIN:LANGUAGE:water_treatment_and_purification -->

Testomat Automatic Hardness Control

Automatic hardness control

The Testomat automatic determines the residual/total hardness via titration. Ideal for the water quality after water softeners, water blender and drinking-water plants.

Testomat ECO

Accurate Titration via piston dosing pump, with display of current measured value.
Two adjustable limits with programmable switch functions.

Technical data:

  • max. operating pressure 1-8 bar
  • operating temperature 10-40°C,
  • automatic time set intervals (0-99 min)
  • indicator solution in 500ml bottles
  • 230V 50Hz.
  • H x W x D = 480 x 380 x 280 cm
  • Weight approx. 9,5 kg
  • IP rating: IP65
  • Datasheet

Testomat 2000

The Testomat 2000 can also determine carbonate hardness, the p-value of the water.
Two separate water input, to monitor multiple plants.

Technical data:

  • max. operating pressure 1-8 bar
  • operating temperature 10-40°C,
  • automatic time set intervals (0-99 min)
  • indicator solution in 500ml bottles
  • 230V 50Hz.
  • H x W x D = 480 x 380 x 280 cm
  • Weight approx. 10,5 kg
  • IP rating: IP65
  • Datasheet


Direct Quotation

For Testomat Eco, 2000
or for Testomat titration liquids

The Testomat Family

Testomat 2000: Automatically determines the residual or total water hardness, the carbonate hardness, the p-value or the minus-m-value via titration. The 2000 can measure two individual measuring points.

Testomat 2000 DUO: This analysis instrument enables the measurement of two different parameters simultaneous, e.g. two different measuring ranges for water hardness.

Testomat 2000 CAL: This Testomat correspond in function and suitability to the Testomat 2000, but has an additional calibration function in order to balance possible interference.

Testomat Eco: This Testomat is "the good value alternative" for the Testomat 2000, it determines through titration the water hardness from a single measurement point. The Testomat Eco or Testomat 2000 replace the Testomat F-bob

Testomat 2000 V: This Testomat version, in combination with a 3/2-way-motor operating valve is an easy to use control system for water blending plant

Testomat 2000 CLT: The process-photometer Testomat 2000 CLT is a wet-chemical online instrument for monitoring the content of total chlorine in the 0–2.5 mg/l (ppm) range and it can be switched to free chlorine.
• Analysis via automatic dosing of 3 reagents; the analysis result is displayed after a reaction time of approx. two minutes
• Application areas: Monitoring of chlorination plants for drinking water or swimming pools– Provides protection for reverse osmosis membranes.

Testomat 2000 CLF: The process-photometer Testomat 2000 CLF is a wet-chemical online instrument for monitoring the content of free chlorine in the0–2.5 mg/l (ppm) range.

Testomat 2000 THCL: The process photometer Testomat 2000 THCL determines the content of total chlorine in the 0 to 2.5 mg/l (ppm) range using the colorimetric analysis principle and the existing water hardness via titration.

Testomat Fe: The process photometer Testomat 2000 Fe is a wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the 0 to 1.0 mg/l (ppm) range using the colorimetric method.
• Dosing of 2 reagents and display of the analysis value after a reaction time of approx. 7 minutes (absolute measuring time without flushing times)

Model

Measuring range

° dH

Ambient temperature

°C

Operating pressure

bar

Water inlet OD

mm

Water outlet OD

mm

Dimensions

B x H x T

mm

Weight

Kg

Application

Testomat 808 0.02 - 3 10 - 40

0.3 - 1

1 - 4

6 6 364 x 314 x 138 4,35

reverse osmosis
water softening

pure water

galvanization

Testomat ECO 0.05 - 25 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9 water treatment
drinking water
Testomat ECO C

0.5 - 10.0 carbonate hardness

1.0 - 20.0 acid capacity

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9

water treatment
drinking water

swimming pools

Testomat EVO TH 0.05 - 25 10 - 40

0.3 - 1

1 - 8

6 12 ID 380 x 480 x 280 9

water treatment
industrial boilers

monitoring proceswater

drinking water

Testomat 2000

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water treatment
water blending

drinking water

watersoftening

decarbonization

desalination

boiler houses

cooling towers

Testomat 2000 CN

0.05 - 25 water harness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water treatment
water blending

drinking water

watersoftening

decarbonization

desalination

boiler houses

cooling towers

Testomat 2000 CAL

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

control water quality

pharmaceutical industry

Testomat 2000 V

1.0 - 25 water hardness

1.0 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

water blending

process water

Testomat 2000 self clean

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

difficult water, calcium, biofilms

extending life

reducing contamination

Testomat 2000 Antox

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

control of water quality

can arise due to oxidizing agents

Testomat 2000 DUO

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

use two circuits for diferent hardness

measurment inlet - outlet

Testomat 2000 DUO CN

0.05 - 25 water hardness

0.5 - 20 carbonate hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

use two circuits for diferent hardness

measurment inlet - outlet

Testomat 2000 CLF free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chlorination

drinking water

swimming pool water

Testomat 2000 CLT free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chlorination

drinking water

swimming pool water

protection RO membranes

Testomat 2000 CLT self clean free chlorine 0.0 - 0.99  / 1.0 - 2.5 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring desinfection

drinking water

process water

Testomat 2000 CLO2 0 - 1.88 / 1.0 - 4.7 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring desinfection

drinking water

process water

Testomat 2000 THCL

free chlorine 0.0 - 0.99 mg/l /

0.25 - 2.50 water hardness

10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

dialysis

corrosion protection

protection RO membranes

monitoring drinking water /swimming pools

Testomat 2000 Br 0 - 2.23 / 2.3 - 5.6 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5 monitoring dosing disinfectants
Testomat 2000 CrVl chromate 0.0 - 0.99 / 1.0 - 2.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring chromate

control of waste water

Testomat 2000 Fe 0.0 - 0.65 / 0.7 - 1.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitorig removing iron

control drinking water

Testomat 2000 Polymer 0.0 - 50.0 mg/l 10 - 45

0.3 - 1

1 - 4

6 6 380 x 480 x 280 9,5 monitoring conditioning cooling and heating
Testomat 2000 PO4 0.0 - 10.0 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

process water

water purification

waste water treatment

Testomat 2000 SO3 sulfite 0.0 - 9.9 / 10 - 20 mg/l 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring sulfite for oxygen binding

boiler water

Titromat KH

5 - 150 °KH

2 - 60 °KH

10 - 45

0.3 - 1

1 - 4

6 6 380 x 480 x 280 9,5 alkalinity of coolant circuits
Titromat M1 0.05 - 1.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring corrosion boiler water

decarbonization

Titromat M2 0.05 - 2.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

monitoring corrosion boiler water

decarbonization

Titromat TH 2.5 - 50.0 10 - 45

0.3 - 1

1 - 8

6 6 380 x 480 x 280 9,5

drinking water

raw water

Indicators and Reagents  

For a direct quotation, please contact us: Feedback Form or call us on +31 152 610 900

 

About Lenntech

Lenntech BV
Rotterdamseweg 402 M
2629 HH Delft

tel: +31 152 610 900
fax: +31 152 616 289
e-mail: info@lenntech.com