Filmtec XLE-440 membrane
Extra Low Energy RO Element.
The FILMTEC™ XLE-440 is an extra low energy, high productivity
brackish water reverse osmosis element designed to deliver high quality
water at low operating costs for municipal and industrial water
applications.. |
 |
| Product name |
XLE-440 |
 |
| Part number |
101060 |
| Nominal Active Surface Area |
440 (41) ft2 (m2) |
| Permeate Flow Rate |
12,700 (48) gpd (m3/d) |
| Stabilized Salt Rejection |
99 % |
| 1. Permeate flow and salt
rejection based on the following test conditions: 500 ppm NaCl, pressure
specified above, 77°F (25°C) and 15% recovery. |
| Membrane Type |
Polyamide Thin-Film Composite (Filmtech) |
| Maximum Operating Temperature |
113°F (45°C) |
| Maximum Feed Flow Rate |
14 (3.2) gpm (m3/hr) |
| Maximum pressure drop |
15 psig (1.0 bar) |
| pH Range, Continuous Operation |
2-11 |
| pH Range, Short Term Cleaning |
1-13 |
| Maximum Feed Silt Density Index |
SDI 5 |
| Free Chlorine Tolerance |
< 0.1 ppm |

| Product Dimensions in Inches (mm) |
A |
B |
C |
|
| XLE-440 |
40.0 (1,016) |
1.5 (38) |
7.9 (201) |
|
Important Information:
Proper start-up of reverse osmosis water treatment systems is essential to
prepare the membranes for operating service and to prevent membrane damage due
to overfeeding or hydraulic shock. Following the proper start-up sequence also
helps ensure that system operating parameters conform to design specifications
so that system water quality and productivity goals can be achieved. Before
initiating system start-up procedures, membrane pretreatment, loading of the
membrane elements, instrument calibration and other system checks should be
completed. Please refer to the application information literature entitled
“Start-Up Sequence” (Form No. 609-02077) for more information.
Operation Guidelines:
Avoid any abrupt pressure or cross-flow
variations on the spiral elements during start-up, shutdown, cleaning or other
sequences to prevent possible membrane damage. During start-up, a gradual change
from a standstill to operating state is recommended as follows: Feed pressure
should be increased gradually over a 30-60 second time frame. Cross-flow
velocity at set operating point should be achieved gradually over 15-20 seconds.
Permeate obtained from first hour of operation should be discarded.
General Information:
Keep elements moist at all times after initial wetting. If operating limits and
guidelines given in this bulletin are not strictly followed, the limited
warranty will be null and void. To prevent biological growth during prolonged
system shutdowns, it is recommended that membrane elements be immersed in a
preservative solution. The customer is fully responsible for the effects of
incompatible chemicals and lubricants on elements. Maximum pressure drop across
an entire pressure vessel (housing) is 50 psi (3.4 bar). Avoid static
permeate-side backpressure at all times.
Notice: The use of this product in and of itself does not necessarily guarantee
the removal of cysts and pathogens from water. Effective cyst and pathogen
reduction is dependent on the complete system design and on the operation and
maintenance of the system. Notice: No freedom from any patent owned by Seller or
others is to be inferred. Because use conditions and applicable laws may differ
from one location to another and may change with time, Customer is responsible
for determining whether products and the information in this document are
appropriate for Customer’s use and for ensuring that Customer’s workplace and
disposal practices are in compliance with applicable laws and other governmental
enactments. Seller assumes no obligation or liability for the information in
this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.
The FILMTEC™ XLE-440 is an extra low energy, high productivity brackish water
reverse osmosis element designed to deliver high quality water at low operating
costs for municipal and industrial water applications. Its high active area
design coupled with the highly productive XLE membrane makes FILMTEC XLE-440 the
lowest pressure RO element – resulting in lower energy costs.
•
XLE-440 will operate in many systems at less than half the feed pressure of a
standard high rejection RO element and at up to 30% less pressure than other low
energy membranes, resulting in lifetime energy savings greater than 100% of the
initial membrane investment. With 440 square feet (41 square meters) of active
membrane area, the FILMTEC XLE-440 element gives system designers the option of
designing a system with fewer membrane elements, requiring lower capital
expenditures for membranes and compenents. Automated, precision fabrication
allows for the industry’s highest active membrane area without compromising the
thickness of the feed spacer, resulting in less fouling, less cleaning downtime
and lower operating costs than competitive products using thinner spacers.
XLE-440 is perfectly suited for cold water feeds as the element’s high
productivity will deliver lower energy costs and/or higher permeate flow.